about log error No response from iLO for Hello
HP AHCI driver for DL360e Gen8?
Hello, I own an HP DL360e Gen8 server running Windows Server 2016.
When I use the B120i or P420i controller for storage, I get the HD Max sensor to show up in iLO4 under System Information / Temperatures. When that sensor gets a reading from the hard drives, the server fans spin down to 18 - 23%.
Since I am using SSDs, I want to either switch the B120i to Intel AHCI mode or use an H220 HBA in order to have TRIM support.
When I do so, there is no RAID driver running, so there is no HD Max sensor in iLO, so the fans spin up to 43% in order to keep the disks cool. The iLO, does not know what the temperature of the disks is and as such raises the fan speed to uncomfortable levels, increasing noise and power consumption.
Is there any driver for the HP Intel AHCI onboard controller or for the HP H220 HBA that can work together with the Agentless Management Service and iLO 4 in order for iLO to get an HD Max sensor reading and spin down the fans?
Edit: pci id of the Intel C600 AHCI controller is 8086:1d02
Issue with Firmware update for EG1200FDJYT drives-Error " The software will not be installed on ...
HI All,
I have an issue with my Gen 10 DL 360 server with windows server 2016 installed ,this server got three HDD of Model EG1200FDJYT ,the current firmware version is HPD1 and i was trying to update the firmware using cp029255 ( which is the correct version for this model HDD ) and it throws error like "The software will not be updated on this system because the required hardware is not present in the system or the software/firmware doesnot apply to the system" .I am 200% sure that the hardware present in my system and also software is correct .Any idea why it is failing and how to fix this ?
Thanks In advance.
Installation of Windows 2016 Server
Hi,
We are going to implement Windows 2016 Server on our company servers. Before we need to know if they are compatible or not. But i cant find a list of compatibility as our servers are quite old.
Anyone can please tell me if they are compatible with windows 2016 Server??
DL380p Gen8
DL380 G7
ML370 G5
ML370 G4
DL360 G5
ML570 G2
Thank you!
HP Drive Array Accelerator Status 0
Hi, I Have HPE DL380 Gen8 .
I have no error in ILO.
But out monitoring tools show hardware error about battery:
HP Drive Array Accelerator Status 0
do you know why this has occurred? and what is the problem?
is there a way to fix that?
look at this picture please:
note: I don't use it's cache.
HPE DL380 Gen10 No Controllers Detected
Hi,
I purchased new sever hp DL380 Gen10 when i am trying to enter in smart storage administrator (SSA version 3.40.3.0). On the next screen under smart array controllers " NO CONTROLLERS DETECTED" cannot create logical drives
Thanks in advanced
ILO Amplifier Upgrade
Currently running ILO Amplifier 1.30 on VMware 6.5 and want to upgrade to 1.40. The user guide only talks about upgrading using a BIN file. The only download I can find is the OVA for 1.40.
How can I upgrade my appliance?
Replace Assigned Harddisk
Hi all, i am sorry in advance if my question is already in this forum, but i haven't got the answer. So here is the case i faced.
I have a server with 2 Harddisk 300GB (RAID 0) with Centos for the operating system. Is it OK if i take out both of the harddisk,. and replace with another two then I install, let's say, Windows Server inside?
Are both harddisk (the one with Centos and the other with Windows) will be fine? or any step that I have to do in case i would like to do this?
Many thanks in advance, need some advice.
New Stencils
Good day, I'm working on some designs for the data center, at work.
And I require some stencils for hard disk, but I can not locate them in Visio Cafe, could you help me?
The model is:
HPE 875652-001 240GB SATA DS SFF HOT SWAP SC SSD FOR PROLIANT GEN9 AND GEN10 SERVERS.
Thanks!
The DL20 Gen10 with GPU
Hi, i have a customer that has an application that uses the processor's GPU. He needs a rack mount server with GPU and it seems the DL20 offers processors with GPU. The question then is, does the server itself disable the GPU or will he be able to utilize it?
Thanks in advanced.
Memory error in remote console access
Hello good day.
Hardware: ML110 G9
Software: iLO 2.70, Windows Server 2016.
I try to access the system via the remote console, but I get this memory reading error. I searched the Google reference number, but nothing related to that number came out. When I restart the server, the console works again, but over time it stops working. Thank you.
Error flashing NVRAM, IP reinstall DL380e Gen8, error for the Embedded Flash/SD-CARD
Hello i need to reinstall system and configure new RAID but Intelligent provisioning dont start (black screen).
I try reinstall IP with dvd but with version 1.63 and 1.71 have the same error "Error flashing NVRAM"
I update ILO to 2.70, update bios to P73 05/24/2019 and reset NVRAM using System Maintenance Switch.
Always have the same error, looking for this problem i find this: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-c04996097
With this steeps:
Step 1) Upgrade the iLO 4 firmware to version 2.61
Step 2) Perform a NAND format
Step 3) Check the iLO status If the iLO status is normal, then skip to Step 6 If the iLO status is still degraded, continue to Step 4
Step 4) Schedule downtime; AC power-cycle and repeat the NAND format
Step 5) Check the iLO status If the iLO status is normal, continue to
Step 6 If the iLO status is still degraded, then skip to Step 7
Step 6) Perform these final steps if the system board does not need to be replaced: Reboot the server; reinstall IP; and refresh the server in OneView (if server is managed by OneView)
Step 7) If steps 1-4 did not resolve the degraded iLO, replace the system board.
I perform the NAND format but have the same error "iLO 4 self-test error for the Embedded Flash/SD-CARD", and when try update IP have the same error "Error flashing NVRAM"
Any can help to fix it? or other way to create raid and install windows?
Thanks.
ProLiant DL380 G7 CPU question
Greetings everyone!
I am upgrading a few older HP ProLiant DL380 G7 servers and would like to know if the Xeon E7-4860 ten core CPU is a compatible processor. I can't get a straight answer from several of the vendors that I use.
Any help would be greatly appreciated.... Thank you.
Smart Storage Administrator Stuck at "Loading"
I have a ProLiant ML150 G6 with Intel Xeon Processor E5504 and HP Smart Array B110i SATA RAID Controller with two Seagate IronWolf 2TB ST2000VN004 drives configured as a RAID array.
BIOS is 2011.01.18
B110i firmware is v1.20 (displayed during POST)
B110i driver is 6.18.4.64
OS is Windows Server 2019
HP SSA version is 3.40.3.0.
HP Smart Array SAS/SATA Event Notification Service version is 6.46.0.64
From within Windows, the drives appear as "HP LOGICAL VOLUME SCSI Disk Device".
When I try to start HP SSA, it gets stuck "Loading". I previously had version 2.40.13.0 installed and it did the same thing. How can I get it to load?
DL380p Gen8 - Orange power but not turn on
I have an DL380P Gen8, the server was sit on data center rack turned off for about 1 year or more, its the same configuration from the factory, nothing changed.
Then when trying to power on, only the power led remain orange, no blinking but no power on, nothing on Diagnostic Panel, i tried several times and nothing, the UUID button not working too, nothing!
I inspected the board, striped most components, cleaned PSU contacts etc, still nothing.
On the main board there's a LEDs called Port 84 from 7 to 0, after some time the 7 lit and after some seconds start to blink.
And there's 3 other LEDs on the board, but 2 lit:
Trying to access iLo or ping the IP was not working, but theirs a LED on iLO port, after some network check i found iLo getting some IP from DHCP, i tried access with all know password, but unsuccessfully. Then cleared NVRAM and set iLO insecure, but turning on 1 and 6 on DIP Switches block, and still nothing, always says wrong password, even the default on from the label, and there's something odd on iLO name, its now iLO-------x in the name, where x is random, but is supposed to be iL0+serial or something, when SSH ask user and password but all incorrect too.
So, i cant power on the server and cant access iLO to check what is going on, and have no idea what the Port 84 LEDs means, anyone have an idea?
HP DL380 Gen10 P - Adding Additional Drives
Hi Everyone, wondering if I could have some advice on a DL380 server.
I currently have a DL380 Gen10 Performance in production but it only has 8 SFF drive bays.
I'm in the process of building another server which is also a DL380 Gen10 but will require 16 SFF drive bays.
Does anyone know the part numbers to do this? I was also going to use a HPE Smart Array P816i-a SR Gen10 to handle the additional drives.
Thanks for your help!
ML110 Gen 10 memory
I am looking at the ML110 gen 10 and the part list show the max memory to be 32GB. Is it possible to use 64GB memory (815101-B21) listed for the ML350 in these slots? The specs look the same apart from the 64G modules are quad rank.
Memory for hp proliant ML v2
Hi,
I want to buy 8gb memory for hp proliant ML v2, but not sure which is correct
I purchased one module, but did not work.
Can you help me?
Thank you
hp smart array p410 slowing down
dear all,
can anyone help me.
I have a backup destination storage server with the following specs:
HP DL180 G6
P410 smart array controller with 1GB cache, 6.64 firmware, 75% read 25% write cache settings with NO battery however it is set to still enable the cache when no battery is present
3 x Disk Arrays are configured, array 1 is for the operating system and has 2 x 4TB disks in RAID 1
the other 2 x arrays each have 4 x 8TB disks with a RAID 10 setup
Windows 2012 R2
48GB RAM
2 x Intel E5620 cpus
the 2 x non OS disk arrays which are used to store the backup files are encrypted with Bitlocker and have dedup enabled to run during the day when no backups are running. Each disk array is setup as a 14.5TB NTFS disk. Now I realise the recommended max size for a windows 2012 r2 dedup disk is 10TB and mine is 14.5TB but I don't think this is related to the issue, but I suppose it is an orangey-red flag.
So basically when I run a disk speed test program checking for the writes and reads I normally get around 300MB both ways which I am happy about considering they are encrypted etc I have also run this during backups and I still get around 300MB.
So the problem I have is after a full night's worth of backups and often when backups are still running, occasionally I get very very poor disk speed checks on writes and reads sometimes like 5MB! This will cause the backups to be delayed and in some cases fail which is not good. Also worth mentioning when I run the disk speed program I also get poor results on the OS disk array which is not encrypted or deduped, so thats why I'm thinking it related to the disk controller.
Is it possible the HP Smart Array cache is running out of memory or that there is a memory leak somewhere - possibly relating to the firmware version?
I also get this problem occasionally on another almost identical backup storage server, so I don't think it is a hardware fault.
Any help is much appreciated.
Mike
DL380p Temperature Sensor 12
Hi.
I have a DL380p that did a shutdown 2 time yesterday, and when i go through syslog i se this.
hpHelper[35466]: WARNING: System Overheating (Temperature Sensor 12, Location System, Temperature 81C)
hpHelper[35466]: CRITICAL: Automatic Operating System Shutdown Initiated Due to Overheat Condition
sfcb-vmware_raw[36417]: IpmiIfcFruGetInv: Failed during send cc = 0xc9
sfcb-vmware_raw[36417]: IpmiIfcFruGetInv: Failed during send cc = 0xc9
sfcb-vmware_raw[36417]: IpmiIfcFruGetInv: Failed during send cc = 0xc9
sfcb-vmware_int[35260]: --- handler could not derive port number
init: starting pid 37847, tty '': '/usr/lib/vmware/vmksummary/log-bootstop.sh stop'
init: starting pid 37850, tty '': '/bin/shutdown.sh'
VMware[shutdown]: Stopping VMs
hpHelper[35466]: NOTICE: Automatic Operating System Shutdown Due to Overheat Aborted
hpHelper[35466]: NOTICE: System Overheating (Temperature Sensor 12, Location System, Temperature 81C) has been repaired
Now I'm trying to find out more exactly what sensor 12 is monitoring, can someone help?
I think i looked everywhere.
Regards
Bo.