I have a HP ProLiant DL380p, with a RAID5 with 4 disks, where I had 2 logical disks running on those disks. Yesterday, I notice that I had one disk with the followin status: Degraded Predictive failure()
And after that, I check all the Integrated Management Log's, and I check that there was also some other caution warnings, that I dont know if are related with this disk or not, since the number of the slot is different, but since it is placed inside of a RAID5, dont know if the disk that have failed some SMART test is already messing with other disks:
"id","Severity","Class","Last Update","Initial Update","Count","Description",
"111"," Caution","POST Message","08/17/2019 13:23","08/17/2019 13:23","1","POST Error: 1720-Slot X Drive Array - S.M.A.R.T. Hard Drive(s) Detect imminent failure",
"110"," Caution","POST Message","08/17/2019 13:23","08/17/2019 13:23","1","POST Error: 1716-Slot X Drive Array - Unrecoverable Media Errors Detected on Drives during previous Rebuild or Background Surface Analysis (ARM) scan. Errors will be fixed automatically when the sector(s) are overwritten.",
"109"," Caution","POST Message","08/17/2019 12:55","08/17/2019 12:46","2","POST Error: 1720-Slot X Drive Array - S.M.A.R.T. Hard Drive(s) Detect imminent failure",
"108"," Caution","POST Message","08/17/2019 12:55","08/17/2019 12:46","2","POST Error: 1716-Slot X Drive Array - Unrecoverable Media Errors Detected on Drives during previous Rebuild or Background Surface Analysis (ARM) scan. Errors will be fixed automatically when the sector(s) are overwritten.",
"107"," Caution","POST Message","08/16/2019 17:52","08/16/2019 17:08","4","POST Error: 1720-Slot X Drive Array - S.M.A.R.T. Hard Drive(s) Detect imminent failure",
"106"," Caution","POST Message","08/16/2019 17:52","08/16/2019 17:08","4","POST Error: 1716-Slot X Drive Array - Unrecoverable Media Errors Detected on Drives during previous Rebuild or Background Surface Analysis (ARM) scan. Errors will be fixed automatically when the sector(s) are overwritten.",
"105"," Caution","Drive Array","08/17/2019 13:24","07/28/2019 05:32","16","Internal Storage Enclosure Device Failure (Bay 1, Box 2, Port 1I, Slot 0)",
"104"," Caution","POST Message","07/23/2019 18:40","07/23/2019 18:40","1","POST Error: 1716-Slot X Drive Array - Unrecoverable Media Errors Detected on Drives during previous Rebuild or Background Surface Analysis (ARM) scan. Errors will be fixed automatically when the sector(s) are overwritten.",
"103"," Caution","POST Message","07/23/2019 10:40","07/23/2019 10:29","2","POST Error: 1716-Slot X Drive Array - Unrecoverable Media Errors Detected on Drives during previous Rebuild or Background Surface Analysis (ARM) scan. Errors will be fixed automatically when the sector(s) are overwritten.",
"102"," Caution","POST Message","07/12/2019 13:23","07/12/2019 13:23","1","POST Error: 1716-Slot X Drive Array - Unrecoverable Media Errors Detected on Drives during previous Rebuild or Background Surface Analysis (ARM) scan. Errors will be fixed automatically when the sector(s) are overwritten.",
"101"," Repaired","Network","06/26/2019 13:13","06/26/2019 13:11","1","Network Adapter Link Down (Slot 0, Port 2)",
"100"," Repaired","Network","06/26/2019 13:13","06/26/2019 13:11","1","Network Adapter Link Down (Slot 0, Port 1)",
"99"," Repaired","Network","06/26/2019 12:15","06/26/2019 12:13","1","Network Adapter Link Down (Slot 0, Port 2)",
"98"," Repaired","Network","06/26/2019 12:15","06/26/2019 12:13","1","Network Adapter Link Down (Slot 0, Port 1)",
"97"," Repaired","Network","06/26/2019 13:14","06/25/2019 18:13","3","Network Adapters Redundancy Reduced (Slot 0, Port 3)",
"96"," Repaired","Network","06/25/2019 18:15","06/25/2019 18:13","1","Network Adapter Link Down (Slot 0, Port 2)",
"95"," Repaired","Network","06/26/2019 13:14","06/25/2019 18:11","3","Network Adapters Redundancy Reduced (Slot 0, Port 2)",
"94"," Repaired","Network","06/25/2019 18:13","06/25/2019 18:09","1","Network Adapter Link Down (Slot 0, Port 1)",
"93"," Caution","POST Message","06/03/2019 19:45","06/03/2019 19:45","1","POST Error: 1716-Slot X Drive Array - Unrecoverable Media Errors Detected on Drives during previous Rebuild or Background Surface Analysis (ARM) scan. Errors will be fixed automatically when the sector(s) are overwritten.",
"92"," Caution","POST Message","05/31/2019 13:13","05/31/2019 13:13","1","POST Error: 1716-Slot X Drive Array - Unrecoverable Media Errors Detected on Drives during previous Rebuild or Background Surface Analysis (ARM) scan. Errors will be fixed automatically when the sector(s) are overwritten.",
"91"," Caution","POST Message","04/30/2019 13:16","04/30/2019 13:09","2","POST Error: 1716-Slot X Drive Array - Unrecoverable Media Errors Detected on Drives during previous Rebuild or Background Surface Analysis (ARM) scan. Errors will be fixed automatically when the sector(s) are overwritten.",
"90"," Caution","POST Message","03/20/2019 13:55","03/20/2019 13:55","1","POST Error: 1716-Slot X Drive Array - Unrecoverable Media Errors Detected on Drives during previous Rebuild or Background Surface Analysis (ARM) scan. Errors will be fixed automatically when the sector(s) are overwritten.",
"89"," Repaired","Network","03/19/2019 19:07","03/19/2019 19:05","1","Network Adapters Redundancy Reduced (Slot 0, Port 2)",
"88"," Repaired","Network","03/19/2019 19:07","03/19/2019 19:05","1","Network Adapters Redundancy Reduced (Slot 0, Port 3)",
"87"," Repaired","Network","03/19/2019 19:05","03/19/2019 19:04","1","Network Adapter Link Down (Slot 0, Port 2)",
"86"," Repaired","Network","03/19/2019 19:05","03/19/2019 19:04","1","Network Adapter Link Down (Slot 0, Port 1)",
"85"," Caution","POST Message","03/13/2019 11:37","03/13/2019 11:37","1","POST Error: 1716-Slot X Drive Array - Unrecoverable Media Errors Detected on Drives during previous Rebuild or Background Surface Analysis (ARM) scan. Errors will be fixed automatically when the sector(s) are overwritten.",
"83"," Caution","POST Message","03/09/2018 16:27","03/09/2018 16:27","1","POST Error: 1792-Slot X Drive Array - Valid Data Found in Cache Module. Data will automatically be written to drive array.",
Regarding the predictive failure disk, since it is a hot swap controller, I think that I just need to replace that disk, by disconnect it and add a identical disk with the same model, to start the replication from RAID5, during production time or not. If its less danger to do it with that server offline I can do it that way.