Quantcast
Channel: ProLiant Servers (ML,DL,SL) topics
Viewing all 10362 articles
Browse latest View live

How often is FWPP updated?

$
0
0

Hi

rsyncing FWPP allows us to keep a good stock of most relevant firmware available internally, but I saw that it lags behind compare to what is available using the web downloads.

Here are 3 examples between FWPP vs. web download:

  • DL380 Gen9 UEFI 2.72 vs. 2.74,
  • Intel NIC firmware 1.17.17 vs. 1.18
  • QLogic NC2 firmware 2.24.15 vs. 2.25.10

Is there anything HPE can share as to how often the FWPP team syncs its repository with the web download sources?


Ayuda con Proliant ML30 Gen 10 P06785-S01

$
0
0

Saludos comunidad. recientemente adquirimos un servidor Proliant Ml30 Gen 10 P06785-S01 ya que el servidor que actualmente trabaja tiene daños que hay que repara. Quisiera saber si podemos instalar windows server 2019 standard sin licencias cal ya que por tratarse de una oficina pequeña y solo se trabaja con un sistema de manera local y la situación que actualmente vivimos en nuestro país no nos permite realizar muchos gastos. Si podemos instalar sólo el windows server 2019 standard con su licencia servidor nos basta. Gracias por su recomendación.

 

Google Translation

Greetings community. We recently acquired a Proliant Ml30 Gen 10 server P06785-S01 since the server that is currently working has damages that need to be repaired.
I would like to know if we can install windows server 2019 standard without lime licenses since since it is a small office and only one system is working locally
and the situation we currently live in our country does not allow us to make many expenses.
If we can install only the windows server 2019 standard with its server license, it is enough for us. Thanks for your recomendation.

 

Proliant DL380 G7 Boot error

$
0
0

Hello Experts ,

I am getting "Slot 0 HP Support Array p410i Controller " error when server gets booted and unable to go further from this point.

Exact error message is 1783-Slot 0 Drive Array Controller failure.

[command failure (cmd=0h,err=08h,diu=013)

 

i tried to upgrade the firware version avaialable in hpe sites but no luck.

Can anybody help me to resolve this issue ?

 

proliant service pack error

$
0
0

I have 2 ML350p gen 8 servers running windows server 2008R2 that i'm trying to update using the last proliant service pack :

P19089_001_SPP-2019.03.1-SPP2019031.2019_0425.6.ISO (5.66 GB)

after inventory , i receive the following warning : 

Deploy may encounter issues due to the following warning(s):

 
Warning - The selected Firmware Baseline is not supported for the given server. It is not recommended to continue with the updates using this baseline. Please select a different supported baseline for this server.
To proceed with the updates using this baseline at your own risk, select Ignore Warnings option.
 
What should i do ?! how to know which updates have the issue ?! 

HP ProLiant DL380 G7 (Nvidia GTX 1050ti) DOESNT RECOGNIZE HELP!!!

$
0
0

Hi I have a HP ProLiant DL380 G7. I purchased on EBAY a NVIDIA GTX 1050ti graphics card. I tested the Pci-e port with another graphics card and it displays the output fine. The GTX 1050 graphics card says it needs no extra power it runs under 75w. So I installed with no extra power supply cable. The fans spin on the graphics card when I plug it in and there are no beeps on bootup. There is absolutely no video output I tried on the Display port and Digital DVI output port. I do not have a hdmi cord to try that port. I did no bios configuration and have no idea of how to get this card to work. The riser card was moved to the left side and installed in (Left configuration) since there are 2 spots you can have the riser installed. I put it in the left configuration so I can fit the GTX 1050. What can I do to fix this????? please help

intelligent provisioning SMB/CIFS (Windows Share) "missing"

$
0
0

I installed an OS via SMB several times on a DL20 Gen10.  Now intelligent provisioning SMB/CIFS (Windows Share) "missing"

Hello every one

$
0
0
Hello hope to get help here and give new advices

How to remove VID drive in DL560 Gen10

$
0
0

Dear everyone,

We just reinstalled our DL560 Gen10, due to it still keep rebooting randomly.

We installed Server 2016 from Intelegence Provisioning, choosing manual installation, instead of Assisted Installation. For testing purpose, we're not plug-in the any LAN cable/ Internet Cable to the server, so it just DL560 Gen10 with keyboard, mouse, external dvdrom to install. Without MSA, without anything, we unplugged the unused like fibre cables.

After we successfuly installed Windows Server 2016, we found an unknown drive in Explorer, named VID, size 509MB, write protected. We could not remove it, unless we uninstalled it from device manager, named iLO LUN 00 Media 0 USB Device.

Any idea how to remove/ disable it? We read the previous discussion and the RBSU seems different from DL560 Gen10 had.

Thank you.

 

 


DL360 G7 pre-POST Problems, accidental short. (Solved, Ish)

$
0
0

Hi all.

So i got this DL360 G7, and after a year of the mind numming drone from the server, I decided to convert it to a tower server and slap in some watercooling.

All went surprisingly well, until i had to extend the SAS backplane power cables, where i accidentaly reversed the wires and shorted something. (I have fixed the cable corectly now btw)

Now the Health LED flashes Red and nothing on the SID, Starting the system powers it up for a second and goes to standby again, and does this no matter the config, except when no cpu's are present., the fans also spin up for a hot second.

I have exhausted the manuals and flow-charts and the only info that has given me, is that theres a System Board Fault.

So i was wondering if theres any Debug tools or a pinout for the SAS Power cable? i suspect i killed a voltage regulator or something, on the SAS Power Cable im getting 2xGND 1x12v 2x3.3v and a 2.8v??? is the 2.8v correct or should it have been 5v maybe?

INFO

DL360 G7 2x X5650 maxed out with 192GB RAM (Motherboard 602512-001) 2x 460W PSU's (505908-001 Controller)

Also, this is a secondhand server i got from a school, and being 18 i don't have the money to spend on a new motherboard, so im willing to fix the board myself, and i do have good experience in THT and SMT Soldering.

Hope you can help me

Best regards - Gustav K. Andersen

SOLUTION

So I ended up finding a good price on a refurbished Board. and then il'll keep the other board for spares i guess.

COPROCESSOR IN DEVICE MANAGER for HPE Proliant ML350 g6

$
0
0

I have an old HPE Proliant ML350 g6 and the only Driver that I need after upgrading to Server 2019 is the Coprocessor Driver. 

I cannot find a driver for the coprocessor, .

I would appreciate if someone could help.

Thank you!!

HPE Proliant ML30 - the Host OS run back when the Processor Core Disable = 1

$
0
0

Dear All,

my Server is HPE Proliant ML30 Gen 9.

Host OS is ESXI 6.5.0 

RAM 64G, in each 16G in 4 slot 

CPU xeon E3-1240v5 

it turn to PSOD after run in 2 years.

-------------------------------------------------

check IML:

Uncorrectable Machine Check Exception (Board 0, Processor 0, APIC ID 0x00000006, Bank 0x00000000, Status 0xBD800000'00000006, Address 0x00000000'00000000, Misc 0x000007FE'8A97D000)

And when i change core diable in BIOS from [0] to [1]

the host run back.

Question:

- CPU broken or not, do i need to replace cpu?

- can i run the host as normal with this situation?

- why i change the processor core diable = 1 per socket the host OS work again as CPU not failed?

-  what is the meaning of the processor core diable?

Thanks all for your time

no eligible disk found : hp, dl380 g10

$
0
0

bonjour,

j'ai un probleme avec la detection des disques dures avec ce serveur ,

card raid : HPE SMART ARRAY P408I-a SR GEN10 : ACTIVé

HPE SMART ARRAY S100I SR GEN10 : Desactivé

disque : 10 k sas ds 300gb 872735

malgré ça je reçois le message :NO ELIGBLE DISK FOUND AU MOMENT DU CONFIGURATION D'un array.

merci pour votre soutien.

Google Translate:
I have a problem with the detection of hard disks with this server,
card raid: HPE SMART ARRAY P408I-a SR GEN10: ON
HPE SMART ARRAY S100I SR GEN10: Disabled
record: 10 k sas ds 300gb 872735
in spite of that I receive the message: NO ELIGBLE DISK FOUND AT THE TIME OF CONFIGURATION OF an array.
Thank you for your support.

 

 

Can you install Proxmox on an HP DL380p Gen8?

$
0
0

Hallo Leute,

ich habe einen HP DL380p Gen8 und würde am liebsten darauf Proxmox installieren um die eingebuaten Grafikkarten ( RTX 2070, Radeon) an eine  Windows 10 VM durchreichen damit ich in Blender diese verwenden kann. Aber irgendwie will das nicht so wirklich funktionieren.

Jemand eine Idee wie man das machen muss ? für eine Anleitung wäre ich sehr dankbar.

Google Translated

Hi folks,

I have a HP DL380p Gen8 and would like to install Proxmox on it to pass the onboard graphics cards (RTX 2070, Radeon) to a Windows 10 VM so that I can use them in Blender. But somehow that does not really work.

Someone an idea how to do that? I would be very grateful for a tutorial.

MFG 

Kirito

Server gets Down Automatically

$
0
0

Dear All,

    Good Day ! We have a server proliant DL380 G9. which was working fine and now it gets down automatically  but no crash in OS level. 

Done few troubleshoot but it will get up & running for few days again it will be down. Kindly rectify.

Nividia Tesla K40 not working properly on Hp Proliant ML350p Gen 8

$
0
0

I'm trying to connect my Nvidia Tesla K40 with my Hp Proliant ML350P.

Specs: HP Proliant ML350P Gen 8 Tower

DUAL e5-2670 V1 CPU

32gb DDR3 RAM

Dual 750W PSU

350GB Raid, 500gb SSD and 2Tb Disc HD

OS: Windows 10 Pro. Hardware is stable with OS.

I had connected an Nvidia Gtx 1060 6gb GPU and it worked great using a 6pin power cable and was stable.

I then took the GTX 1060 out and put in an Nvidia Tesla k40 (passive heat sink) but was unable to get it to work/register in bios when plugging 6pin and 8pin power. However, it was able to register/detect the Tesla K40 without the power cables and just using the PCI-e power. However when that was the case, I received the Code 12 lack of resources error message in the device manager,

Nvidia Tesla k40 is in the servers quick spec manual as compatible, so would be great to hear from you experts of any other technicalities that may be preventing it from working/registering when the 6pin and 8pin are connected.

 

Thanks in advance.

 

Cheers Mark


HPE Proliant DL385 GEN 10 Windows server Installation and Smart Array problems

$
0
0

Dears,

 

Good day, I have issues with HPE Proliant DL385 GEN 10 Installation and Smart Array,  when I create the smart array and tryed to install both windows server 2012 r2 and 2016 the smart array is not showing, the problem is when I enter the windows installation window the array which created is not listed there,

is there any recommendations from your side may I try to fix these issue.

Please note that I am not professional in HPE products so please explain everything in details.

Thanksin advance.

Upgrade ESXi6.0 to 6.7 with custom image

$
0
0

Hello,

I could download and sucessefully install the custom image from HP of ESXi 6.0 U3 that contains the drivers for our Proliant DL360e Gen8.

I would like to upgrade into ESXi 6.7 but There's not custom image for the server Proliant DL360e Gen8.

Anyone allready install the ESXi 6.7 on a this server? Any tips?

thanks in advance!

doa82

Device discovery in progress. Refresh the page in a few minutes.

$
0
0

Good afternoon, colleagues!
Today, one server suddenly launched Device discovery, this process has been going on for 16 hours, someone has encountered a similar problem, what is better to do in such situations?

ProLiant DL380 G6 Fan failure

$
0
0

Hello everyone,

One of the 6 fans in my ProLiant DL380 G6 server stopped working recently, causing the machine to gracefully shutdown in a few hours, due to insufficient cooling capacity (even though the machine was idle).

I opened the server and swapped around the failing fan, only to find out that it worked flawlessly in other sockets. Conversely, any of the other functional fans that I placed in the socked of the initially failing fan did not work at all, so it seems that it's the socked that is faulty. Also, in the process of performing these tests, the adjacent socket seems to have become faulty as well.

I have visually checked the pins in the connectors and they are fine. Also, I have measured with a multimeter the voltage of the 12V pin in both faulty sockets and it was close to 0V (a few tens of millivolts), whereas the other fuctional sockets showed the expected 12V.

The machine is quite old and I don't have a service contract. It seems to be a motherboard problem, but I am not sure if something can be done to recover (part of) the functionality.

Any comments/suggestions will be much appreciated.

Best regards,

CRLS

 

 

 

 

 